Sunlu AMS Filament Dryer / Heater for Bambu AMS Systems

Description

This SUNLU AMS Heater is compatible with the Bambu Lab AMS - Automatic Material System.

Please note that this product is optimized and upgraded exclusively for Bambu Lab's AMS (1st gen), and is not compatible with Automatic Material Systems from other Brands.

Regarding the visibility of the lid, the entire lid is not fully transparent. There is a transparent area on the front of the lid that allows you to see the internal operation.

Drying and printing are performed simultaneously. This is a heater that can upgrade the upper cover of the AMS. Compared to the traditional printing process using the AMS, which requires drying before printing, the upgraded version allows for simultaneous printing and drying.

Unique Air Duct Design. The innovative airflow system directs heat to circulate precisely around the filament area, ensuring efficient drying while protecting the AMS feeding motor from high temperatures. This design may also cause slight temperature and humidity differences between electronic components.

High-efficiency heating with uniform temperature distribution, reaching 70°C within 20 minutes. The dual airflow design ensures even heat circulation, preventing localized overheating of materials and effectively reducing the risk of thermal deformation.

High compatibility: After upgrading to the AMS Heater, it supports stacked 16-color printing and saves space. Upgrades the heater for the AMS Generation 1 upper cover, seamlessly integrating with the Generation 1 seal strip and fully compatible with the Generation 1 seal preservation function.

Simple upgrade process: Loosen—disassemble—tighten, completed in just 2 minutes.

Intelligent humidity monitoring:
① Humidity mode default heating temperature: 55°C—users can adjust and save the temperature.
② Default operating time: 6 hours.
③ After the countdown ends, the device does not shut down; it automatically starts heating when humidity rises to 50% and stops heating when humidity drops to 20%.
④ In rH mode, users can adjust humidity (range: 25%–50%).
After adjustment, the humidity automatically starts using this set value.

Safe and Reliable:
PTC heating. Dual-level protection with a temperature control switch. Software-based intelligent temperature control, real-time temperature monitoring, and automatic control of the heating system. Maximum drying temperature of 70°C. Alarms are triggered when the temperature exceeds the set value by 10°C, when the temperature fails to rise, or when the fan malfunctions. The device operates according to the set time and automatically shuts down when the time reaches zero.

Product dimensions
363mm × 278mm × 131mm (LWH)

Outer box dimensions
415mm × 316mm × 190mm

Product net weight
1.7KG

Temperature setting range
35°C–70°C

Humidity display range
See display: 10%-90%

Time setting range
0-99H

Power input specifications
AC 110V 60Hz or AC 220V 50Hz

Maximum operating current
2.2A@230V 4.15A@120V

Maximum operating power
390W

Standby power
0.6W

Rated power
220W

Drying and printing are performed simultaneously

This is a heater that can upgrade the upper cover of the AMS. Compared to the traditional printing process using the AMS, which requires drying before printing, the upgraded version allows for simultaneous printing and drying.

[rH] Intelligent Humidity Monitoring Mode

① Humidity mode default heating temperature: 55°C—users can adjust and save the temperature.

② Default operating time: 6 hours.

③ After the countdown ends, the device does not shut down; it automatically starts heating when humidity rises to 50% and stops heating when humidity drops to 20%.

④ In rH mode, users can adjust humidity (range: 25%–50%).
After adjustment, the humidity automatically starts using this set value.

20 mins to 70℃

High-efficiency heating with uniform temperature distribution, reaching 70°C within 20 minutes. The dual airflow design ensures even heat circulation, preventing localized overheating of materials and effectively reducing the risk of thermal deformation.

About the rH Mode

When the AMS heater is in "rH Mode", the display screen will remain on after the countdown ends, and the "Time" indicator will show "Close".

In "rH Mode", the default humidity threshold is set to 50%. When the humidity exceeds 50%, the AMS heater will start heating.

Users can adjust the activation threshold for "rH Mode" within a range of 25% to 50%, depending on their needs.

For example, if set to 25%, the heater will activate once the humidity exceeds 25%. When the humidity drops to 20%, the AMS heater will stop heating and switch to standby mode.

SKU
SUN3881 (West3D)

Vendor Pricing & Availability

West3D

Updated: 4 hours ago

$79.99

Free Shipping

Buy Now →

Store links may be affiliate links: we may earn a commission at no extra cost to you.

Advertisement

Price history

Lowest price each day

$79.99

Collecting price history

We have one day of prices so far. The trend line appears after at least two days.

View as table
Date West3D
Nov 17, 2026 $79.99

Advertisement

Zeb · 1d ago

Message hidden until you log in.
B

bob · 1d ago

Message hidden until you log in.
B

bob · 1d ago

Message hidden until you log in.
B

bob · 1d ago

Message hidden until you log in.
B

bob · 1d ago

Message hidden until you log in.
B

bob · 1d ago

Message hidden until you log in.

Eck · 1d ago

Message hidden until you log in.

7 recent messages, hidden until you log in. Log in or sign up to read the chat and join in.

Send private messages to other members.

Log in