LDO LCP300-24D5 300W 24V and 5V Compact Power Supply (PSU)
Description
The LCP300-24D5 is a compact, fully enclosed 300W dual-output power supply for 3D printing applications. Featuring power factory correction and Gallium Nitride technology, the LCP300-24D5 provides 24V and 5V outputs with an efficiency of over 90%.
Features
Dual output: 24VDC (x3) and 5VDC (x1)
Highly compact (120×95×35mm) and fully enclosed
GaN technology with PFC and efficiency of up to 91%
Overload, overvoltage, and temperature protection
Wide AC input: 100-240VAC
Dual AC input terminals, supporting AC series connection
Model Breakdown
Electrical Specifications
Model
LCP300-24D5
Output
Output Voltage
5V
24V
Max Current
5A
11.45A
Max Power
25W
275W
Ripple & Noise (Max)2
150mVp-p
360mVp-p
Line Regulation
±1%
±1%
Load Regulation
±5%
±2%
Start-up / Rise Time3
3000ms/115VAC,≤100ms/220VAC
Hold-up Time4
≥8.3ms at full load
Input
Voltage Range
100 - 240VAC
Frequency Range
50-60Hz
Efficiency
≥91%
AC Current
3.5A/115VAC 2A/230VAC
Inrush Current
≤50A/220VAC cold start
Leakage Current
≤0.75mA, 240VAC/50Hz
L/N Terminal Current5
12A Max
Protection Features
Overload Protection
≥110% of rated output power
5.2-6A (5V), 13-17A (24V), output voltage shuts off; recovers automatically after fault removal
Overvoltage Protection
≥135% of rated output voltage
Output voltage shuts off; recovers automatically after fault removal
Temperature Protection
When enclosure surface temperature exceeds 110°C
Output voltage stops until temperature drops below 80°C
Environmental Conditions
Operating Temperature
-20~40℃
Operating Humidity
10~90%
Storage Temperature & Humidity
-30~85℃/ 5~90%
Vibration
10-500Hz, 2G, 10 minutes/cycle, 60 minutes in each X, Y, and Z direction
Safety & Compliance
Safety Standards
High Voltage Resistance
2.5KVAC
Insulation Resistance
≥100MΩ
EMC Immunity
Compliant with EN/IEC: EN55032
Harmonic Standards
Compliant with IEC61000-3-2
Others
Dimensions
120.0mm (L) * 95.0 mm (W) * 35.0 mm (H)
Packaging
132x105x39mm
MTBF
50000h (25℃)
Notes
Unless otherwise specified, all specifications are measured under 230VAC input, rated load, and 25°C ambient temperature.
Ripple and noise measurement: Measured at the end of the output cable, with a 0.1μF ceramic capacitor and a 47μF electrolytic capacitor.
Start-up time: The time from when power is applied to the input until the output voltage rises to 90% of its rated value. Rise time: The time required for the power supply to reach its rated output value from a no-power state.
Hold-up time: The duration from when the AC input is cut off to when the output drops below 5% of the standard value.
L/N terminal current: Refers to AC voltage interface, where a single input is used to distribute one output. The maximum current the AC voltage interface can withstand is 12A.
For more information please see LDO Docs.
- SKU
- LDO5400 (West3D)
Vendor Pricing & Availability
West3D
Updated: 6 hours ago
$68.99
Free Shipping
Store links may be affiliate links: we may earn a commission at no extra cost to you.
Advertisement
Price history
Lowest price each day
$68.99
Collecting price history
We have one day of prices so far. The trend line appears after at least two days.
View as table
| Date | West3D |
|---|---|
| Nov 17, 2026 | $68.99 |
Advertisement